| Pressure Calibrator, Multifunctional |
|
|
| Model No.︰ | ECP4600 |
| Brand Name︰ | Henry |
| Country of Origin︰ | - |
| Minimum Order︰ | - |
|
|
| The portable pressure calibrator is best for field calibration, commissioning and maintenance of both instruments and their control loops, with capabilities of pressure and electric measurement, data storage, as well as facilities for 4 to 20 mA loop testing. It is equipped with different ranges of pressure generating hand pump to form an easy calibration system. The hand pump is built with fine pressure control. The rugged industrial design is styled without compromising the visibility of the larger parameter display. The file storage function offers memory of up to 60 sets of instruments including information of tag numbers and calibration data. |
|
|
|
| Specifications︰ | Technical Specifications
Pressure accuracy and ranges: Reading -13 to 5800 PSI (-90kPa to 40MPa) with below standard ranges: Resolution 1 Pa and accuracy 0.075%FS: 0 to 10, 16, 20 kPa and -16 to 0, -10 to 0, -10 to 10, -16 to 16 kPa Resolution 1 Pa and accuracy 0.05%FS: 0 to 16, 20, 25, 40, 60 kPa and -16 to 0, -10 to 0, -10 to 10, -16 to 16 kPa Resolution 10 Pa and accuracy 0.05%FS: 0 to 100, 160, 200, 250, 400 kPa and -90 to 0 kPa, 0 to 0.4, 0.6 MPa Resolution 100 Pa and accuracy 0.05%FS: 0 to 1.0, 1.6, 2.0 MPa Resolution 1 kPa and accuracy 0.05%FS: 0 to 10, 16, 20, 40 MPa
Electric accuracy and ranges: Voltage: 0-200V, accuracy 0.05% FS Current: 0-30mA, accuracy 0.05% FS Output power for loop: Output Power: 24V DC +/-5%, max. 50mA. Temperature: Wider, from 5 to 40 deg. C. Process connection: 1/4”NPT or 1/4”BSP Sizes / Weight: 150×140×90mm /1.0kg
Optional Accessories: Hand Pumps: Range from -13 to 8700 PSI (-90kPa to 60Mpa), with 1 Pa to 1 kPa increment fine vernier. Carrying Case: Optional foam stuffed aluminum case helps integrating the system together. The specifications are subject to change without advance notice. |
| Advantages︰ | Features - Pressure transducer: high linear, long term stability and temperature compensation; - Microprocessor based, press to zero pressure, mA and voltage drift; - Built-in rechargeable 6V DC cells and outer fast charger for 220V AC 50Hz power supply; - Engineering unit selected from MPa /mH2O /mHg /PSI, or kPa /mmH2O /mmHg /PSI; - Larger display: simultaneously indicate pressure, percentage and mA or voltage, soft menu and information column also; - Out connected hand pump of wider ranges with fine vernier and vent valve. |
|
|
|
|
|
|
|